190 lines
8.0 KiB
HTML
190 lines
8.0 KiB
HTML
|
|
<h2>Introduction</h2>
|
|
<p>
|
|
An engineer reading and using audio level meters compares to a musician
|
|
reading or writing sheet-music. Just like there are virtuoso musicians
|
|
who can't read a single note, there are great sound-engineers who just
|
|
go by their ears and produce great mixes and masters without ever looking
|
|
at a single meter.
|
|
</p>
|
|
<p>
|
|
Yet, in order to work in or with the broadcast industry, it is
|
|
usually unavoidable to use meters.
|
|
</p>
|
|
<p>
|
|
Audio level meters are very powerful tools that are useful in every
|
|
part of the entire production chain:
|
|
</p>
|
|
<ul>
|
|
<li>When tracking, meters are used to ensure that the input
|
|
signal does not <dfn>overload</dfn> and maintains reasonable
|
|
<dfn>headroom</dfn>.</li>
|
|
<li>Meters offer a <dfn>quick visual indication</dfn> of an
|
|
activity when working with a large number of tracks.</li>
|
|
<li>During mixing, meters provide an rough estimate of the
|
|
<dfn>loudness</dfn> of each track.</li>
|
|
<li>At the mastering stage, meters are used to check
|
|
compliance with upstream <dfn>level</dfn> and <dfn>loudness
|
|
standards</dfn> and to optimize the <dfn>loudness range</dfn>
|
|
for a given medium.</li>
|
|
</ul>
|
|
|
|
<h2>Meter Types</h2>
|
|
<p>
|
|
A general treatise on metering is beyond the scope of this
|
|
manual. It is a complex subject with a history…
|
|
For background information and further reading we recommend:
|
|
</p>
|
|
<ul>
|
|
<li><a href="http://www.digido.com/how-to-make-better-recordings-part-2.html">How To Make Better Recordings in the 21st Century—An Integrated Approach to Metering, Monitoring, and Leveling Practices</a> by Bob Katz. Has a good historic overview of meters and motivates the K-meter</li>
|
|
<li><a href="https://en.wikipedia.org/wiki/Peak_programme_meter#Table_of_characteristics">Wikipedia: Peak programme meter</a>—overview of meter types.</li>
|
|
<li>"Audio Metering: Measurements, Standards and Practice: Measurements, Standards and Practics", by Eddy Brixen. ISBN: 0240814673</li>
|
|
<li>"Art of Digital Audio", by John Watkinson. ISBN: 0240515870</li>
|
|
</ul>
|
|
|
|
<p>
|
|
There are different metering standards, most of which are available in Ardour. In short:
|
|
</p>
|
|
|
|
<table class="dl">
|
|
<tr><th>Digital peak-meter</th>
|
|
<td>A <dfn>Digital Peak Meter</dfn> displays the absolute maximum signal
|
|
of the raw audio PCM signal (for a given time). It is commonly used when
|
|
tracking to make sure the recorded audio never clips. To that end, DPMs
|
|
are always calibrated to 0 <abbr title="DeciBel Full
|
|
Scale">dBFS</abbr>, or the maximum level that can be represented digitally
|
|
in a given system. This value has no musical reason whatsoever and depends
|
|
only on the properties of the signal chain or target medium. There are
|
|
conventions for <dfn>fall-off-time</dfn> and <dfn>peak-hold</dfn>, but no
|
|
exact specifications.
|
|
<p>
|
|
Various conventions for DPM fall-off times and dBFS line-up level can be
|
|
chosen in <kbd class="menu">Edit > Preferences > Metering</kbd>.
|
|
</p>
|
|
</td></tr>
|
|
|
|
<tr><th>RMS meters</th>
|
|
<td>An <dfn><abbr title="Root Mean Square">RMS</abbr>-type meter</dfn>
|
|
is an averaging meter that looks at the energy in the signal. It
|
|
provides a general indication of loudness as perceived by humans. Ardour
|
|
features three RMS meters, all of which offer additonal peak indication.
|
|
<ul>
|
|
<li><dfn>K20</dfn>: A meter according to the K-system introduced by Bob
|
|
Katz, scale aligned to -20 dBFS, rise/fall times and color schema
|
|
according to spec.</li>
|
|
<li><dfn>K14</dfn>: Same as K20 with scale aligned to -14 dBFS.</li>
|
|
<li><dfn>K12</dfn>: Same as K20 with scale aligned to -12 dBFS (since 3.5.143).</li>
|
|
<li><dfn>Peak + RMS</dfn>: standard RMS, customizable via
|
|
<kbd class="menu">Edit > Preferences > Metering</kbd></li>
|
|
</ul>
|
|
</td></tr>
|
|
|
|
<tr><th>IEC PPMs</th>
|
|
<td><dfn><abbr title="International Electrontechnical Commission">IEC</abbr>-type
|
|
<abbr title="Peak Programme Meters">PPM</abbr>s</dfn> are a mix between DPMs and
|
|
RMS meters, created mainly for the purpose of
|
|
interoperability. Many national and institutional varieties exist (<abbr
|
|
title="European Broadcasting Union">EBU</abbr>, <abbr title="British Broadcasting
|
|
Corporation">BBC</abbr>, <abbr title="Deutsche Industrie-Norm">DIN</abbr>).
|
|
<p>
|
|
These loudness and metering standards provide a common point of
|
|
reference which is used by broadcasters in particular so that the
|
|
interchange of material is uniform across their sphere of influence,
|
|
regardless of the equipment used to play it back.
|
|
</p>
|
|
<p>
|
|
For home recording, there is no real need for this level of
|
|
interoperability, and these meters are only strictly required when
|
|
working in or with the broadcast industry. However, IEC-type meters have
|
|
certain characteristics (rise-time, ballistics) that make them useful
|
|
outside the context of broadcast.
|
|
</p>
|
|
<p>
|
|
Their specification is very exact, and consquently, there are no
|
|
customizable parameters.
|
|
</p>
|
|
</td></tr>
|
|
|
|
<tr><th>VU meters</th>
|
|
<td><dfn><abbr title="Volume Unit">VU</abbr> meters</dfn> are the dinosaurs (1939)
|
|
amongst the meters. They react very slowly, averaging out peaks.
|
|
Their specification is very strict (300ms rise-time, 1–1.5% overshoot,
|
|
flat frequency response). Ardour's VU meter adheres to that spec, but for
|
|
visual consistency it is displayed as a bar-graph rather than needle-style
|
|
(more below).
|
|
</td></tr>
|
|
</table>
|
|
|
|
<h2>Ardour Specifics</h2>
|
|
|
|
<figure class="right">
|
|
<img src="/images/mixer-meter-context-menu.png" alt="mixer strip meter context menu">
|
|
<figcaption>
|
|
Mixer strip meter context menu
|
|
</figcaption>
|
|
</figure>
|
|
|
|
<p>
|
|
Meters are available in various places in Ardour:
|
|
</p>
|
|
<ul>
|
|
<li>The mixer window features fixed height meters for each <dfn>channel strip</dfn>.</li>
|
|
<li>There are small (narrow) meters on each <dfn>track-header</dfn> in the editor window.</li>
|
|
<li>There are variable height meters in the <dfn>meterbridge window</dfn>.</li>
|
|
<li>Optionally, a fixed-size <dfn>master meter</dfn> can be displayed in the main toolbar.</li>
|
|
<li>Various other locations (<dfn>file import</dfn>, <dfn>sends</dfn>) have level-meters.</li>
|
|
</ul>
|
|
<p>
|
|
They all share the same configuration and color-theme which is available in
|
|
preferences and the theme-manager. Settings for the Peak and RMS+Peak meters
|
|
as well as VU meter standards are found in
|
|
<kbd class="menu">Edit > Preferences > Metering</kbd>.
|
|
</p>
|
|
|
|
<p>
|
|
The type of meter and the <dfn>metering point</dfn> (the place in the signal chain
|
|
where the meter taps the signal) are configurable in the context menu of each meter.
|
|
Depending on the <kbd class="menu">Edit > Preferences > Mixer</kbd> settings,
|
|
the metering point is also accessible via a button in each Mixer strip.
|
|
</p>
|
|
|
|
<p>
|
|
Regardless of meter type and standard the meter display will highlight red if
|
|
the signal on the given channel exceeds the configured peak threshold.
|
|
</p>
|
|
<p>
|
|
<kbd class="mouse">Left</kbd> clicking on the peak-indicator button resets the
|
|
<dfn>peak-hold indicator</dfn> of a single channel.<br>
|
|
<kbd class="mod1 mouse">Left</kbd> clicking resets a whole <dfn>group</dfn>, and<br/>
|
|
<kbd class="mod13 mouse">Left</kbd> clicking resets all meters.
|
|
</p>
|
|
|
|
<h2>Overview of meter types</h2>
|
|
|
|
<figure class="left">
|
|
<img class="mini" src="/images/meter-types-18.png" alt="Bar-graph meters in Ardour">
|
|
<figcaption>
|
|
Bar-graph meters in Ardour
|
|
</figcaption>
|
|
</figure>
|
|
|
|
<figure class="right">
|
|
<img class="mini" src="/images/needle-meters-18.png" alt="Needle-style meters as external LV2 plugins">
|
|
<figcaption>
|
|
Needle-style meters as external LV2 plugins
|
|
</figcaption>
|
|
</figure>
|
|
|
|
<p>
|
|
The figure on the left shows all available meter-types in Ardour when fed with a
|
|
-18 dBFS 1 kHz sine wave.
|
|
</p>
|
|
|
|
<p>
|
|
Due to layout concerns and consistent look and feel all meters available in
|
|
Ardour itself are bar-graph type meters. Corresponding needle-style
|
|
meters—which take up more visual screen space—are available as
|
|
LV2 plugins (see image on the right):
|
|
<a href="https://github.com/x42/meters.lv2/">meters.lv2</a>.
|
|
</p>
|