<p>
Extenders will require a custom file as there are no combinations listed
at this time. The best way is to start with the mc.device file and copy it
to a new name such as xt+mc.device and then edit that file. It is best to
name the file with the order the devices are expected to be used in as
the position of the master device is specified in this file.
</p>
<p>
The two lines of interest are:
<p>
<pre>
&lt;Extenders value="0"/&gt;
&lt;MasterPosition value="0"/&gt;
</pre>
<p>
Add these two lines if they are not present. The <code>Extenders</code>
value is the number of extenders used and should not include the master in
that number.
</p>
<p>
When an <code>Extenders</code> value of greater than 0 is used, extra midi
ports will appear for the extenders to be connected to. The MIDI ports
for the controllers will be named <code>mackie control #1</code>,
<code>mackie control #2</code> and up. The numbers will go from left to
right. That is, from lowest number channel to highest.
</p>
<p>
The <code>MasterPosition</code> value is the port number the master unit
(with the master fader) is connected to. So if there are three surfaces,
<code>&lt;MasterPosition value="1"/&gt;</code> will expect the master on
the left, <code>&lt;MasterPosition value="2"/&gt;</code> would be master
in the middle and <code>&lt;MasterPosition value="3"/&gt;</code> would be
master on the right. So the position matches the port name.
</p>
<p class="note">
The default value of <code>&lt;MasterPosition value="0"/&gt;</code> has
the same effect as <code>&lt;MasterPosition value="1"/&gt;</code>.
</p>
<p>
If the <code>MasterPosition</code> value does not properly match the
physcal position and MIDI port, the master fader and global controls will
not work. The master unit will act like an extender.
</p>