The Monitor section is an optional feature that provides Control Room/Monitor Speaker outputs. It can be activated for the current session in the Session > Properties window by enabling the Use monitor section in this session option in the Monitoring tab. By default the Monitor Section is fed with audio from the Master Bus, but depending on solo mode and other functions such as Auditioning, other audio sources may be temporarily heard instead.
The Monitor section appears on the right hand side of the Mixer, and comprises:
The Status indicators, two of which also appear in the Transport tool bar, flash to indicate when that function is in operation:
The SiP, PFL and AFL controls inter-cancel with each other and select the desired Solo mode. Excl. Solo and Solo Mute then modify the modes behaviour. See Muting and Soloing. The current mode is indicated by the illuminated 'LED' on the button.
SiP | This selects Solo In Place as the current solo mode and cancells the previous mode. |
---|---|
PFL | This selects Pre Fade Listen as the current solo mode and cancells the previous mode. |
AFL | This selects After Fade Listen as the current solo mode and cancells the previous mode. |
Excl. Solo | This enables or disables the Exclusive Solo option. |
Solo » Mute | This enables or disables the Solo Mute option. |
Changing the solo mode (SiP, PFL or AFL) will update the labels on the mixer strips' solo controls accordingly.
Clicking the Processors button show or hides the Monitor Sections processor box. This is used in the same way as processor boxes present in tracks and busses. It can be used to insert pugins, e.g. a room correction EQ or a specific metering type.
As this processing is local to the Monitor Section it is only applied to audio that is ultimately available at the monitor outputs.
These controls set the level of the audio when a channel or bus solo is engaged.
Solo Boost | This is the level that will be added to the current main monitor level when a track or bus is soloed, providing a conveniant boost in level for the isolated signal. The rotary control has a range of 0dB to +10dB and can be set at any point between these two values. A drop down menu with pre-defined values is also provided for convenience. |
---|---|
SiP Cut | Only relevant to Solo in Place mode. This sets the level that all muted tracks or busses will be muted by. By default it is -&infinity; i.e. the non soloed tracks are totally inaudible. The level can be raised to make the other tracks audible, though dimmed. This is also sometimes referred to Solo in Front. The rotary control has a range of -inf to +0dB and can be set at any point between these two values. A drop down menu with pre-defined values is also provided for convenience. |
The Dim level control sets the amount by which the monitoring will be reduced when a Dim button is engaged. The rotary control has a range of -20dB to 0dB and can be set at any point between these two values. A drop down menu with pre-defined values is also provided for convenience.
Each of the individual paths through the Monitor Section, (e.g. L and R for stereo), can be controlled individually. Four functions are available:
Mute | Mutes the selected path(s) |
---|---|
Dim | Reduces the selected path(s) level by the amount set with the Dim level control |
Solo | Soloes the selected channel(s) |
Inv | Inverts the selected channel(s) polarity |
Those buttons directly affect the output of the monitoring section:
This control sets the level for Monitor Section output. The rotary control has a range of -inf to +6dB and can be set at any point between these two values. A drop down menu with pre-defined values is also provided for convenience.
Clicking on this button shows a menu that allows quick and convenient routing of the Monitor Section's outputs to audio hardware outputs, e.g. to feed control room monitors. It also has an option to open Ardours routing matrix, where more detailed connectivity is available if routing to something other than hardware is required.