From 1257b9b4b1e36da5a0085433dbdca6255d13d2e9 Mon Sep 17 00:00:00 2001
From: Len Ovens
From the selector at the top, choose the type of device you are using.
- (What do do if your device is not listed).
+ (
+ What do do if your device is not listed).
Once your setup is complete, click "OK" to close the dialog. Now click
diff --git a/_manual/22_using-control-surfaces/02_devices-using-mackielogic-control-protocol/04_devices_not_listed.html b/_manual/22_using-control-surfaces/02_devices-using-mackielogic-control-protocol/04_devices_not_listed.html
new file mode 100644
index 00000000..bfb9136b
--- /dev/null
+++ b/_manual/22_using-control-surfaces/02_devices-using-mackielogic-control-protocol/04_devices_not_listed.html
@@ -0,0 +1,18 @@
+---
+layout: default
+title: What to if your Device is not Listed
+menu_title: Unlisted devices
+---
+
+
+ All Mackie Control devices are based on the original Logic Control and the
+ documentation in the user manual that came with it. The Mackie Control and
+ the Mackie Control Pro and so on, all use this same protocol. Any units
+ from other manufactures will also use the same encoding as best the
+ hardware will allow. If the unit in use has more than one Mackie Control
+ option, it is best to choose Logic Control or LC. Any Templates for the
+ buttons should be chosen the same way as the Function key Editor uses these
+ button names. The "Mackie Control" option should be considered default and
+ should be tried with any unlisted device before attemping to create a
+ custom definition file.
+
+ Extenders will require a custom file as there are no combinations listed
+ at this time. The best way is to start with the mc.device file and copy it
+ to a new name such as xt+mc.device and then edit that file. It is best to
+ name the file with the order the devices are expected to be used in as
+ the position of the master device is specified in this file.
+
+ The two lines of interest are:
+
+
+ Add these two lines if they are not present. The
+ If the
+ >Extenders value="0"/>
+ >MasterPosition value="0"/>
+
+Extenders
+ value is the number of extenders used and should not include the master in
+ that number. That is, it should be the total number of units minus 1. The
+ MasterPosition
value is the position from left to right where
+ the master unit (with the master fader) is, starting at 0. So if there are
+ three surfaces, MasterPosition
with value 0 would be master
+ on the left, MasterPosition
with value 1 would be master in
+ the middle and MasterPosition
with value 2 would be master on
+ the right.
+MasterPosition
value does not properly match the
+ physcal position and MIDI port, the master fader and global controls will
+ not work. The master unit will act like an extender.
+
+ The sysex=
and msg=
bindings will only work with
+ function=
or action=
control addresses. They
+ will not work with the uri=
control addresses.
+
A control address defines what the binding will actually control.