add dedicated line-up level for IEC1/DIN meter (15dbFS)
This commit is contained in:
parent
d4c864d803
commit
ff9296e17c
@ -85,8 +85,8 @@ LevelMeterBase::set_meter (PeakMeter* meter)
|
||||
}
|
||||
}
|
||||
|
||||
static float meter_lineup(float offset) {
|
||||
switch (Config->get_meter_line_up_level()) {
|
||||
static float meter_lineup_cfg(MeterLineUp lul, float offset) {
|
||||
switch (lul) {
|
||||
case MeteringLineUp24:
|
||||
return offset + 6.0;
|
||||
case MeteringLineUp20:
|
||||
@ -101,6 +101,10 @@ static float meter_lineup(float offset) {
|
||||
return offset;
|
||||
}
|
||||
|
||||
static float meter_lineup(float offset) {
|
||||
return meter_lineup_cfg(Config->get_meter_line_up_level(), offset);
|
||||
}
|
||||
|
||||
static float vu_standard() {
|
||||
// note - default meter config is +2dB (france)
|
||||
switch (Config->get_meter_vu_standard()) {
|
||||
@ -148,7 +152,7 @@ LevelMeterBase::update_meters ()
|
||||
} else if (meter_type == MeterIEC1NOR) {
|
||||
(*i).meter->set (meter_deflect_nordic (peak + meter_lineup(0)));
|
||||
} else if (meter_type == MeterIEC1DIN) {
|
||||
(*i).meter->set (meter_deflect_din (peak + meter_lineup(3.0)));
|
||||
(*i).meter->set (meter_deflect_din (peak + meter_lineup_cfg(Config->get_meter_line_up_din(), 3.0)));
|
||||
} else if (meter_type == MeterIEC2BBC || meter_type == MeterIEC2EBU) {
|
||||
(*i).meter->set (meter_deflect_ppm (peak + meter_lineup(0)));
|
||||
} else if (meter_type == MeterVU) {
|
||||
|
@ -1930,10 +1930,25 @@ RCOptionEditor::RCOptionEditor ()
|
||||
mlu->add (MeteringLineUp18, _("-18dBFS (EBU, BBC)"));
|
||||
mlu->add (MeteringLineUp15, _("-15dBFS (DIN)"));
|
||||
|
||||
Gtkmm2ext::UI::instance()->set_tip (mlu->tip_widget(), _("Configure meter-ticks and color-knee point for dBFS scale DPM, set reference/offset level for IEC PPM."));
|
||||
Gtkmm2ext::UI::instance()->set_tip (mlu->tip_widget(), _("Configure meter-marks and color-knee point for dBFS scale DPM, set reference level for IEC1/Nordic, IEC2 PPM and VU meter."));
|
||||
|
||||
add_option (S_("Preferences|GUI"), mlu);
|
||||
|
||||
ComboOption<MeterLineUp>* mld = new ComboOption<MeterLineUp> (
|
||||
"meter-line-up-din",
|
||||
_("IEC1/DIN Meter line-up level; 0dBu"),
|
||||
sigc::mem_fun (*_rc_config, &RCConfiguration::get_meter_line_up_din),
|
||||
sigc::mem_fun (*_rc_config, &RCConfiguration::set_meter_line_up_din)
|
||||
);
|
||||
|
||||
mld->add (MeteringLineUp24, _("-24dBFS (SMPTE US: 4dBu = -20dBFS)"));
|
||||
mld->add (MeteringLineUp20, _("-20dBFS (SMPTE RP.0155)"));
|
||||
mld->add (MeteringLineUp18, _("-18dBFS (EBU, BBC)"));
|
||||
mld->add (MeteringLineUp15, _("-15dBFS (DIN)"));
|
||||
|
||||
Gtkmm2ext::UI::instance()->set_tip (mld->tip_widget(), _("Reference level for IEC1/DIN meter."));
|
||||
|
||||
add_option (S_("Preferences|GUI"), mld);
|
||||
|
||||
ComboOption<VUMeterStandard>* mvu = new ComboOption<VUMeterStandard> (
|
||||
"meter-vu-standard",
|
||||
|
@ -151,6 +151,7 @@ CONFIG_VARIABLE (float, meter_hold, "meter-hold", 100.0f)
|
||||
CONFIG_VARIABLE (float, meter_falloff, "meter-falloff", 32.0f)
|
||||
CONFIG_VARIABLE (VUMeterStandard, meter_vu_standard, "meter-vu-standard", MeteringVUstandard)
|
||||
CONFIG_VARIABLE (MeterLineUp, meter_line_up_level, "meter-line-up-level", MeteringLineUp18)
|
||||
CONFIG_VARIABLE (MeterLineUp, meter_line_up_din, "meter-line-up-din", MeteringLineUp15)
|
||||
CONFIG_VARIABLE (float, meter_peak, "meter-peak", 0.0f)
|
||||
CONFIG_VARIABLE (bool, meter_style_led, "meter-style-led", true)
|
||||
|
||||
|
Loading…
Reference in New Issue
Block a user