Fix music-time parameter automation #9019
Music-time has a significantly reduced resolution. When evaluating parameter automation using sample-time, different samples can be mapped back to the same beat-tick. This can result in endless loops. The same automation event is found again: ``` start: 112640 next_event.when: b13334 -> dist a5892029@a662323200 in dist.samples: 1002 start: 113642 next_event.when: b13334 -> dist a269@a668214960 dist.samples: 0 ``` Note this fix may not be correct, since time-domains are mixed. "end" is using sample-time. Furthermore The loop is only entered if there is an event found using timepos_t(start). Further work will be required (ideally use the same resolution for all time-domains, or force everything that is evaluated in RT-context to a single time-domain)
This commit is contained in:
parent
b634cbba4c
commit
6a55146fdc
@ -1389,7 +1389,7 @@ PluginInsert::automate_and_run (BufferSet& bufs, samplepos_t start, samplepos_t
|
|||||||
|
|
||||||
map_loop_range (start, end);
|
map_loop_range (start, end);
|
||||||
|
|
||||||
if (!find_next_event (timepos_t (start), timepos_t (end), next_event)) {
|
if (!find_next_event (next_event.when, timepos_t (end), next_event)) {
|
||||||
break;
|
break;
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|