Fix automated controllable display value
::automation_run() evaluates the value, possibly ahead of time depending on latency-compensation. The actual value is set in realtime-context via set_value_unchecked() -> actually_set_value() which emits the Changed signal. At this point in time Control::user_value is already set correctly. There is no need to evaluate and interpolate again, at a potentially incorrect (uncompensated) time: `_session.transport_sample()`. This fixes an issue with the GUI Automation control showing an outdated value when there is an "immediate jump" in the signal: eg. add a latent plugin post-fader, then automate the Fader to jump from 0dB to -inf dB (snap to grid) and play though that transition. (Plugin controls were not affected by this bug, the process cycle is split for those, but Mixbus internal AC were affected).
This commit is contained in:
parent
7a01f3cbcd
commit
5cb6e1046b
@ -95,12 +95,14 @@ AutomationControl::writable() const
|
||||
return true;
|
||||
}
|
||||
|
||||
/** Get the current effective `user' value based on automation state */
|
||||
double
|
||||
AutomationControl::get_value() const
|
||||
{
|
||||
bool from_list = alist() && alist()->automation_playback();
|
||||
return Control::get_double (from_list, timepos_t (_session.transport_sample()));
|
||||
/* automation_run() will have updated the value
|
||||
* (possibly ahead of time, according to latency compensation),
|
||||
* and actually_set_value() will have set the user-value accordingly.
|
||||
*/
|
||||
return Control::user_double();
|
||||
}
|
||||
|
||||
double
|
||||
|
@ -106,18 +106,12 @@ SlavableAutomationControl::get_value_locked() const
|
||||
double
|
||||
SlavableAutomationControl::get_value() const
|
||||
{
|
||||
bool from_list = _list && boost::dynamic_pointer_cast<AutomationList>(_list)->automation_playback();
|
||||
|
||||
Glib::Threads::RWLock::ReaderLock lm (master_lock);
|
||||
if (!from_list) {
|
||||
if (!_masters.empty() && automation_write ()) {
|
||||
/* writing automation takes the fader value as-is, factor out the master */
|
||||
return Control::user_double ();
|
||||
}
|
||||
return get_value_locked ();
|
||||
} else {
|
||||
return Control::get_double (true, timepos_t (_session.transport_sample())) * get_masters_value_locked();
|
||||
if (!_masters.empty() && automation_write ()) {
|
||||
/* writing automation takes the fader value as-is, factor out the master */
|
||||
return Control::user_double ();
|
||||
}
|
||||
return get_value_locked ();
|
||||
}
|
||||
|
||||
bool
|
||||
|